What the work involves
Boreholes advanced with Standard Penetration Testing to ASTM D1586, where a split-spoon sampler is driven by a 63.5 kg hammer falling 760 mm and the blows per 150 mm increment are logged as the N-value. Coring recovers continuous samples through rock or stiff strata; test pits expose shallow profiles directly. The output is a logged soil profile, the groundwater level, and samples recovered for laboratory testing.